Reliable F1FR56 Series Upright (RA1425) Fire Sprinkler Head
Sprinkler Identification Number (SIN): RA1425.
This Reliable F1FR56 Series Upright Fire Sprinkler features a Glass Bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each upright head features a brass frame and brass deflector.
The RA1425 is a quick response, standard coverage sprinkler intended for use in light and ordinary hazard occupancies, operating with a maximum working water pressure of 175 PSI. Using a heat-activated glass bulb assembly, this automatic fire sprinkler activates when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin.
This sprinkler delivers effective and adaptable defense against fire in a variety of sprinkler system designs. This low-profile sprinkler may be Installed Exposed in the upright position. If required, the RA1425 may be fitted with an approved Reliable water shield, making it appropriate for use as an Intermediate level sprinkler. For the official and most up to date installation instructions, refer to appropriate data sheet available on the Reliable website.
Reliable Upright F1FR56 Fire Sprinkler (RA1425) Sprinkler Head Listings and Approvals
When installed properly, the RA1425 fire sprinkler head is cULus Listed and FM Approved. For the full list and most up-to-date Listings and Approvals, refer to the manufacturer datasheet.
When using Reliable F1FR56 Series Upright Sprinkler RA1425 for systems designed to NFPA13, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 3 of the datasheet. This pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet piping systems.
Reliable F1FR56 Series Upright (RA1425) Upright Sprinkler Installation and Other Information
During installation, be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 8 to 18 lb-ft (11 to 24 N-m). Refer to the data sheet for additional installation and storage information.
This upright sprinkler features a Brass Finish and a 155F (68C) activation temperature. Available finish options include Brass, Chrome, and White. White Polyester Finish (White) is UL Listed as corrosion resistant. Temperature options include 135F (57C) , 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.
The RA1425 listed accessories include the approved Reliable W2 Standard Sprinkler Wrench (part no. 6880050100), and the approved guards and shields. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.
QRFS SKU: |
RA1425BR155 |
Manufacturer Part Number: |
F1FR56U1BN |
Manufacturer: |
Reliable |
SIN: |
RA1425 |
Model: |
F1FR56 |
Head Type: |
Upright |
Finish: |
Brass |
Finish Detail: |
Brass |
Size: |
1/2 in. |
Size Detail: |
1/2 in. NPT |
K Factor: |
5.6K |
Response Type: |
Quick Response (QR) |
Temperature: |
155F |
Heat Element: |
Glass Bulb |
Coverage: |
Standard Coverage |
Material: |
Brass Frame, Brass Deflector |
Corrosion Resistant: |
No |
May Contain Lead: |
Yes |
UL Listed: |
Yes |
FM Approved: |
Yes |
Hazard Rating: |
Light-Ordinary Hazard |
Maximum Working Water Pressure: |
250 PSI |
Length: |
2.25 in. (57.15 mm) |
Width: |
1.38 in. (35.052 mm) |
Height: |
1.38 in. (35.052 mm) |
Weight: |
0.47 lbs. (0.21 kg) |