Victaulic FireLock FL-SR/SW (V2709) Horizontal Sidewall Fire Sprinkler Head
This Victaulic FL-SR/SW Brass Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 286F (141C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each sidewall head features a brass frame and bronze deflector. The manufacturer part number is S271CJS410, and the Sprinkler Identification Number (SIN) is V2709. In 2019, Victaulic purchased fire sprinkler company Globe. The Globe Equivalent to this sprinkler is GL5670.
Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 286F (141C), drenching the area surrounding a fire to keep it in its place of origin. For recessed sidewall application, refer to data sheet for installation with the Victaulic V27 Recessed Escutcheon.
Victaulic Horizontal Sidewall Fire Sprinkler FL-SR/SW (V2709) Sprinkler Head Listings and Approvals
Each FL-SR/SW sprinkler is made by Victaulic, a global leader in fire-suppression products. This sidewall fire sprinkler head maintains Approvals or Listings from cULus (4-12 in. deflector distance, excl. 286F and 360F with escutcheon), FM (no escutcheon, 1/2 in. escutcheon only, excl. 286F and 360F), LPCB (no escutcheon), and CE (no escutcheon).
The V2709 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This horizontal sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) FM and connects to wet piping systems.
Victaulic FL-SR/SW (V2709) Sidewall Head Sprinkler Installation and Other Information
During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.
This sidewall sprinkler features a brass finish and a 286F (141C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White) and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C), and 360F (182C). Finish and temperature combinations available in the “Options” section at the top of this product page.
V2709 listed accessories include the V27-2 Recessed and V27 Open End sprinkler wrenches and the V27 Recessed Escutcheon. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.
QRFS SKU: |
V2709BR286 |
Manufacturer Part Number: |
S271CJS410 |
Replaces Manufacturer Part Numbers: |
GL5670 |
Manufacturer: |
Victaulic |
SIN: |
V2709 |
Model: |
FireLock FL-SR/SW |
Head Type: |
Sidewall |
Finish: |
Brass |
Finish Detail: |
Plain Brass |
Size: |
1/2 in. |
Size Detail: |
1/2 in. NPT Sprinkler |
K Factor: |
5.6K |
Response Type: |
Standard Response (SR) |
Temperature: |
286F |
Heat Element: |
Glass Bulb |
Coverage: |
Standard Coverage |
Material: |
Brass Frame, Bronze Deflector |
Corrosion Resistant: |
No |
May Contain Lead: |
Yes |
UL Listed: |
Yes |
FM Approved: |
Yes |
Maximum Working Water Pressure: |
175 PSI |
Escutcheon Type: |
Recessed |
Length: |
3 in. (76.2 mm) |
Width: |
1.25 in. (31.75 mm) |
Height: |
1.25 in. (31.75 mm) |
Weight: |
0.21 lb. (0.1 kg) |
Available Box/Pack Quantity: |
100 |