Victaulic® V2704 Upright Sprinkler | QR | 5.6K | White | 135F | S271AAQ440

SKU:
V2704WH135
Manufacturer Part Number:
S271AAQ440

No reviews yet Write a Review
$33.50

Victaulic® V2704 Upright Sprinkler | White | 135F | QRFS | Hero

Victaulic® V2704 Upright Sprinkler | White | 135F | QRFS | Hero
Victaulic® V2704 Upright Sprinkler | White | 135F | QRFS | Side
Victaulic® V2704 Upright Sprinkler | White | 135F | QRFS | Deflector
Play Button

  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Victaulic® V2704 Upright Sprinkler | White | 135F | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Victaulic FireLock FL-QR (V2704) Upright Fire Sprinkler Head

This Victaulic FL-QR White Quick Response Upright Fire Sprinkler features a glass bulb activating at 135F (57C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each upright head features a brass frame and bronze deflector. The manufacturer part number is S271AAQ440, and the Sprinkler Identification Number (SIN) is V2704. In 2019, Victaulic purchased fire sprinkler company Globe. The Globe Equivalent to this sprinkler is GL5615.

Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 135F (57C), drenching the area surrounding a fire to keep it in its place of origin.

Victaulic Upright Fire Sprinkler FL-QR (V2704) Sprinkler Head Listings and Approvals

Each FL-SR sprinkler is made by Victaulic, a global leader in fire-suppression products. This upright fire sprinkler head maintains Approvals or Listings from cULus, FM, LPCB, CE, VdS, CCC ZSTZ-15 (excl. 135F).

The V2704 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) FM, and is UL Listed for 250 PSI (17.2 bar) and connects to wet piping systems.

Victaulic FL-QR (V2704) Upright Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information. If an upright sprinkler head is not installed properly, it may not work as intended.

This upright sprinkler features a white finish and a 135F (57C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

V2704 listed accessories include the V27 Open End sprinkler wrench, and this sprinkler head is commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
V2704WH135
Manufacturer Part Number:
S271AAQ440
Replaces Manufacturer Part Numbers:
GL5615
Manufacturer:
Victaulic
SIN:
V2704
Model:
FireLock FL-QR
Head Type:
Upright
Finish:
White
Finish Detail:
White Polyester Painted
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
135F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI (UL, FM) 250 PSI (UL)
Length:
1.44 in. (36.58 mm)
Width:
1.44 in. (36.58 mm)
Height:
2.5 in. (63.5 mm)
Weight:
0.18 lb. (0.08 kg)
Available Box/Pack Quantity:
100
Reviews
No reviews yet