Victaulic V38 Cover Plate | Custom Color | 135F

SKU:
FCPCUST135

No reviews yet Write a Review
MSRP: $105.50
$91.75
You save $13.75

Victaulic V38 Cover Plate | Custom Color | 135F

Victaulic V38 Cover Plate | Custom Color | 135F
Victaulic V38 Cover Plate | Custom Color | 135F
Victaulic V38 Cover Plate | Custom Color | 135F

  • Buy 100 - 399 and get 5% off
  • Buy 400 or above and get 15% off

Frequently Bought Together:

Victaulic V38 Cover Plate | Custom Color | 135F
Inc. Tax
Ex. Tax
Overview

Custom-Finished 135F (57C) Cover Plate Assembly for Victaulic Model V38 Fire Sprinklers activates at 135F (57C) to facilitate timely activation of fire sprinkler heads with temperatures rated at 135F (57C) to 155F (68C).

Sprinkler Identification Numbers (SIN) for this Custom-Finished 135F (57C) Cover Plate Assembly for Victaulic Model V38 Fire Sprinklers include:

  • V3801
  • V3802
  • V3804
  • V3806
  • V3807
  • V3808

This Custom-Finished 135F (57C) Cover Plate Assembly for Victaulic Model V38 Fire Sprinklers is listed by UL, FM, and/or other organizations depending on the sprinkler. When this custom-finished fire sprinkler cover plate reaches a specified temperature the solder holding the plate's decorative exterior on the frame melts, and the two separate. Cover plates in stock finishes other than custom-finished are available on our site, and custom-finished may be available by special order - call us at 888-361-6662 or click here to contact us.

For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Fire Sprinkler Helpful Tips:

Tip 1: When replacing cover plates it is important to purchase replacements from the same manufacturer as the fire sprinkler. Each manufacturer's plate is a little different in size, color, and so on. The manufacturer and temperature of a cover plate is printed on the base of the plate. To view this information, remove the cover plate. Most cover plates are either twist off or pull off.

Tip 2: Any modifications or replacements to a fire sprinkler system should be performed by qualified professionals.

Tip 3: National Fire Protection Association (NFPA) guidelines state that spare fire sprinkler heads and a wrench should be accessible at all times in a facility with a commercial fire sprinkler system installed. Often, state regulations also apply. Check with your local fire department.

Tip 4: All fire sprinkler systems should be visually inspected (often) and professionally inspected (annually).

Specifications
Finish:
Custom Color
Temperature:
135F
SIN Number:
sin_number=V3801, sin_number=V3802, sin_number=V3804, sin_number=3806, sin_number=V3807, sin_number=V3808
Model:
V38
UL Listed/FM Approved:
No
Inner Diameter:
2-1/16 in.
Outer Diameter:
3-1/4 in.
Reviews
No reviews yet