SALE

*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W

SKU:
VK4680WH175
Manufacturer Part Number:
16876MD/W

No reviews yet Write a Review
$23.50
$21.15

*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W

*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
*OBSOLETE* Viking Freedom Pendent Fire Sprinkler | VK4680 | Residential | 4.9K | White | 175F | Lead Free | 16876MD/W
  • Buy 50 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Inc. Tax
Ex. Tax
Overview

Viking VK4680 Residential Fast Response White Pendent Fire Sprinkler delivers powerful, affordable fire suppression in residential occupancies such as homes and apartments. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), supporting rescue and evacuation efforts by lowering ambient temperatures.

The Viking Model VK4680 has a 4.9 K-Factor and installs with 1/2 in. (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a lead-free design in compliance with the Reduction of Lead in Drinking Water Act, including a white finish, brass frame, brass screw, and a spring sealing assembly made with nickel alloy and PTFE tape.

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model VK4680 sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction.

*OBSOLETE* Sprinkler is no longer manufactured. This Sprinkler has been replaced by the VK468WH175.

Specifications
QRFS SKU:
VK4680WH175
May Contain Lead:
No
Nominal K-Factor:
4.9K
Fire Sprinkler Heat Element:
Glass Bulb
Fire Sprinkler Use Type:
Residential
Fire Sprinkler Head Type:
Pendent
SIN:
VK4680
Thread Type:
NPT
Model:
Freedom
UL Listed/FM Approved:
No
Data & Resources
Reviews
No reviews yet