*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB

SKU:
VK462CP155
Manufacturer Part Number:
15480AB

No reviews yet Write a Review
$114.25

*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB

*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB
*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB
*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB
*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB
*OBSOLETE* Viking Mirage Concealed Pendent Fire Sprinkler | VK462 | Standard/Quick Response | 5.6K | 155F | 13503AB
  • Viking® Mirage Cover Plate | White | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | White | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Polished Chrome | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Chrome | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Copper | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Black | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Bright Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Antique Brass | 135F | 2-3/4 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Polished Chrome | 135F | 3-5/16 in. OD | QRFS | Hero
  • Viking® Mirage Cover Plate | Brushed Chrome | 135F | 3-5/16 in. OD | QRFS | Hero
  • Buy 50 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Inc. Tax
Ex. Tax
Overview

Viking Mirage VK462 Standard and Quick Response Concealed Pendent Fire Sprinkler delivers decorative, competitively priced defense against fire in ordinary-temperature applications. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), reducing the likelihood of flashover and facilitating safe evacuation. It is UL listed as quick response and FM approved as standard response.

The Viking Model Mirage has a 5.6 K-Factor and installs with 1/2 in. (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a brass body, copper deflector, and nickel-alloy sealing assembly with PFTE tape.

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping and may be installed and used in accordance with NFPA 13 and local fire code. Each Model Mirage sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL listed & FM approved, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops. Concealed pendent sprinklers should not be installed where the air pressure above the ceiling is greater than the pressure below, which may prevent or delay sprinkler activation in the event of a fire.

*OBSOLETE* Sprinkler is no longer manufactured. This Sprinkler has been replaced by the VK4621CP155.

Specifications
QRFS SKU:
VK462CP155
Size Detail:
1/2 in. NPT Sprinkler
K-Factor:
5.6K
Response Type:
Standard/Quick Response
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Corrosion Resistance:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
SIN:
VK462
Head Type:
Concealed Pendent
Model:
Mirage
Manufacturer:
Viking
Data & Resources
Reviews
No reviews yet