Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD

SKU:
VK466BR175
Manufacturer Part Number:
13781AD

No reviews yet Write a Review
$17.00

Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD

Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD
Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD
Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD | QRFS | Deflector
Play Button

  • Viking® E-1 Escutcheon | Bright Brass | 1/2 in. Sprinkler | QRFS | Hero
  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

Frequently Bought Together:

Viking® VK466 Pendent Sprinkler | Residential | 5.2K | Brass | 175F | 13781AD
Inc. Tax
Ex. Tax
Overview

Viking Freedom Residential Pendent (VK466) Fire Sprinkler Head

This Viking Freedom Residential Pendent Fire Sprinkler features a glass bulb activating at 175F (79C) with a 5.2 K-Factor, and 1/2 in. NPT threads. Each pendent head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK466. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK466 pendent sprinkler delivers effective, affordable defense against fire residential occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking escutcheon(s).

Viking Pendent Residential Freedom Fire Sprinkler (VK466) Sprinkler Head Listings and Approvals

Each VK466 pendent sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW, NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking Residential Sprinkler VK466 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart in the datasheet.

This residential sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking Micromatic Residential (VK466) Pendent Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This horizontal sidewall sprinkler features a brass finish and a 175F (79C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK466 listed accessories include the approved Viking Wrench (part no. 21475M/B), Viking Recessed Wrench (part no. 13655W/B), and the approved Viking Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
VK466BR175
Manufacturer Part Number:
13781AD
Manufacturer:
Viking
SIN:
VK466
Model:
Freedom
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.2K
Response Type:
Residential
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
1.15 in. (29.21 mm)
Width:
1.4 in. (35.56 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.16 lb. (0.07 kg)
Available Box/Pack Quantity:
50
Reviews
No reviews yet