Reliable® SWC Cover Plate | Off White Painted | 135F | 3-5/16 in. OD | 6887131374

SKU:
11-RA-SWC-FF135
Manufacturer Part Number:
6887131374

No reviews yet Write a Review
$53.25

Reliable® SWC Cover Plate | Off White | 135F | 3-5/16 in. OD | QRFS | Hero

Reliable® SWC Cover Plate | Off White | 135F | 3-5/16 in. OD | QRFS | Hero
Reliable® SWC Cover Plate | Off White | 135F | 3-5/16 in. OD | QRFS | Label
Play Button

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

Frequently Bought Together:

Reliable® SWC Cover Plate | Off White | 135F | 3-5/16 in. OD | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Reliable SWC Domed Horizontal Sidewall Fire Sprinkler Cover Plate

Reliable SWC Off White Fire Sprinkler Domed Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Reliable/RASCO concealed sidewall fire sprinklers.  The SWC domed cover facilitates timely activation of these Reliable concealed sidewall fire sprinkler heads with a temperature rating of 135F (57C) or 165 (74C). The outer diameter of this cover is 3-5/16 in. This domed horizontal sidewall cover has a maximum adjustment of 1/2 in. This Reliable Model SWC Cover features a finished brass plate to go along with a copper plated steel skirt and steel springs.

The Reliable SWC cover plate is a conical concealed cover plate used with compatible horizontal sidewall sprinklers.  It provides a push-on or thread on connection to the sprinkler. This cover plate is available in six finishes. These finishes include White Painted, Chrome, Black Painted, Off White Painted, Bright Brass, and Satin Chrome.  Along with these base finishes, for an additional fee Reliable will custom paint this cover in any finish you prefer, so long as the paint is from Benjamin Moore or Sherwin-Williams. Contact QRFS customer support for more details.

Reliable SWC Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Reliable may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing or threading the cover into the sprinkler’s frame. The recommended hole diameter when installing sprinkler heads using this cover is 2-5/8 in. and protrudes 1-5/8 in. from the ceiling.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C), the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Reliable SWC Cover Plate Finishes, Temperatures, and Listed Accessories

This Reliable SWC fire sprinkler dome is readily available in White Painted, and can be ordered in Chrome, Black Painted, Off White Painted, Bright Brass, and Satin Chrome upon request. It is available in two temperatures: 135F (57C) or 165F (74C). This domed cover plate can be adjusted up to 1/2 in. You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.

This Sprinkler Cover Plate fits the following Reliable concealed sprinkler heads:

  • R3531
  • R6834
  • RA0362
  • RA1564
  • RA3331
  • RA4862
  • RA5962
Specifications
QRFS SKU:
11-RA-SWC-FF135
Manufacturer Part Number:
6887131374
Manufacturer:
Reliable
Model:
SWC
Installation Type:
Push On or Thread On
Adjustment:
1/2 in.
Outer Diameter:
3-5/16 in.
Inner Diameter:
2-3/16 in.
Finish:
Off White
Finish Detail:
Off White Painted
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
No
Length:
3.31 in. (84.07 mm)
Width:
3.31 in. (84.07 mm)
Height:
2.5 in. (63.5 mm)
Weight:
0.31 lb. (0.14 kg)
fmt_variance:
Non-Slotted
Available Box/Pack Quantity:
50
Reviews
No reviews yet