Viking® Flat Sidewall Cover Plate | Polished Chrome | 135F | 3-5/16 in. OD | 16207FA

SKU:
11-VK-16207-CP135
Manufacturer Part Number:
16207FA

No reviews yet Write a Review
$68.50

Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Hero

Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Hero
Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Label
Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Label 2
Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Family
Play Button

  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

Frequently Bought Together:

Viking® Flat Sidewall Cover Plate | Polished Chrome 135F | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking Flat Sidewall Fire Sprinkler Cover Plate

Viking Flat Sidewall (Label No: 16209A) Polished Chrome Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking concealed sidewall fire sprinklers.  The cover facilitates timely activation of these Viking concealed sidewall fire sprinkler heads with a temperature rating of 135F (57C) or 165F (74C). The outer diameter of this cover is 3-5/16 in. This Viking cover plate is available with a 1/4 in. adjustment.

The Viking Flat Sidewall is a cover for sprinkler heads specifically defined by the manufacturer.  It provides a push-on connection into the sprinklers cup. This cover plate is available in nine finishes. These finishes include Painted White, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Ivory Painted, Black Painted, and Polished Chrome.  Along with these base finishes, for an additional fee Viking will custom paint this cover in any finish you prefer. Contact QRFS customer support for more details.

Viking Flat Sidewall Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Viking may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame, and can be adjusted up to 1/4 in. The recommended hole diameter when installing sprinkler heads using this cover is 2-3/16 in.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165 (74C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Viking Flat Sidewall Cover Plate Finishes, Temperatures, and Listed Accessories

This Viking sidewall concealed sprinkler head cover plate is available in Painted White, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Ivory Painted, Black Painted, and Polished Chrome. It is available at a temperature of 135F (57C) or 165F (74C). You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.

Viking is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.

This Sprinkler Cover Plate fits the following Viking concealed sprinkler heads:

  • VK481
  • VK490
  • VK680
  • VK480
  • VK4800
Specifications
QRFS SKU:
11-VK-16207-CP135
Manufacturer Part Number:
16207FA
Manufacturer:
Viking
Model:
Flat Sidewall
Label Number:
16209A
Installation Type:
Push On
Adjustment:
1/4 in.
Outer Diameter:
3-5/16 in.
Inner Diameter:
1-9/16 in.
Finish:
Chrome
Finish Detail:
Polished Chrome
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
Yes
Length:
3.31 in. (84.07 mm)
Width:
3.31 in. (84.07 mm)
Height:
1.05 in. (26.67 mm)
Weight:
0.24 lb. (0.11 kg)
Available Box/Pack Quantity:
50
Reviews
No reviews yet