Viking Mirage ELO Fire Sprinkler Cover Plate
Viking Mirage ELO (Label No: 14923A) Black Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking concealed fire sprinklers. The Mirage ELO cover facilitates timely activation of these Viking concealed fire sprinkler heads with a temperature rating of 135F (57C) or 165F (74C). The outer diameter of this cover is 2-3/4 in. This Viking cover plate is available with a 1/2 in. adjustment.
The Viking Mirage ELO is a cover for sprinkler heads specifically defined by the manufacturer. It provides a thread-on connection into the sprinklers cup. This cover plate is available in four finishes. These finishes include Polished Chrome, Painted White, Painted Ivory, and Painted Black. Along with these base finishes, for an additional fee Viking will custom paint this cover in any finish you prefer. Contact QRFS customer support for more details.
Viking Mirage ELO Cover Plate Sprinkler Head Compatibility and Listings
This Sprinkler Head Cover Plate from Viking may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply threading the cover into the sprinkler’s frame, and can be adjusted up to 1/2 in. The recommended hole diameter when installing sprinkler heads using this cover is 2-5/8 in.
To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.
When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) or 165F (74C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.
Viking Mirage ELO Cover Plate Finishes, Temperatures, and Listed Accessories
This Viking Mirage ELO concealed sprinkler head cover plate is available in Polished Chrome, Painted White, Painted Ivory, and Painted Black. It is available at a temperature of 135F (57C) or 165F (73C). You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.
Viking is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.
This Sprinkler Cover Plate fits the following Viking concealed sprinkler heads:
- VK469
- VK538
- VK636
QRFS SKU: |
11-VK-23495-BL135 |
Manufacturer Part Number: |
23495MA/B |
Manufacturer: |
Viking |
Model: |
Mirage ELO |
Label Number: |
14923A |
Installation Type: |
Thread On |
Adjustment: |
1/2 in. |
Outer Diameter: |
3-5/16 in. |
Inner Diameter: |
2-3/8 in. |
Finish: |
Black |
Finish Detail: |
Painted Black |
Temperature: |
135F |
Corrosion Resistant: |
No |
UL Listed: |
Yes |
FM Approved: |
No |
Length: |
3.31 in. (84.07 mm) |
Width: |
3.31 in. (84.07 mm) |
Height: |
1.09 in. (27.69 mm) |
Weight: |
0.22 lb. (0.1 kg) |
Available Box/Pack Quantity: |
50 |