Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD

SKU:
VK486CH175
Manufacturer Part Number:
17315FD

No reviews yet Write a Review
$22.75

Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Hero

Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Hero
Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Side
Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Deflector
Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Family

  • Viking® E-1 Escutcheon | Polished Chrome | 1/2 in. Sprinkler | QRFS | Hero
  • Viking® E-2 Escutcheon | Polished Chrome | 1/2 in. Sprinkler | QRFS | Hero
  • Viking® E-3 Escutcheon | Polished Chrome | 1/2 in. Sprinkler | QRFS | Hero
  • Viking® G-1 Escutcheon | Polished Chrome | 1/2 in. Sprinkler | QRFS | Hero
  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

Frequently Bought Together:

Viking® VK486 Sidewall Sprinkler | Residential | 4.0K | Chrome | 175F | 17315FD | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking Freedom Residential Response Horizontal Sidewall (VK486) Fire Sprinkler Head

This Viking Freedom Residential Sidewall Fire Sprinkler features a glass bulb activating at 175F (79C) with a 4.0 K-Factor, and 1/2 in. NPT threads. Each horizontal sidewall head features a brass frame and bronze deflector. The Sprinkler Identification Number (SIN) is VK486. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK486 sidewall sprinkler delivers effective, affordable defense against fire in residential occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking escutcheon(s).

Viking Horizontal Sidewall Fire Sprinkler Freedom (VK486) Sprinkler Head Listings and Approvals

Each Freedom sidewall sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW), and is VdS Approved. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking Residential Horizontal Sidewall Sprinkler VK486 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on the datasheet. This sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking Residential Freedom (VK486) Sidewall Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This horizontal sidewall sprinkler features a chrome finish and a 175F (79C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK486 listed accessories include the approved Viking Wrench (part no. 21475M/B), Viking Recessed Wrench (part no. 13655W/B), and the approved Viking Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
VK486CH175
Manufacturer Part Number:
17315FD
Manufacturer:
Viking
SIN:
VK486
Model:
Freedom
Head Type:
Sidewall
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT
K Factor:
4.0K
Response Type:
Residential
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted or Vaulted/Sloped
Length:
2.44 in. (61.98 mm)
Width:
0.88 in. (22.35 mm)
Height:
1.35 in. (34.29 mm)
Weight:
0.17 lb. (0.08 kg)
Available Box/Pack Quantity:
50
Reviews
No reviews yet